4) Amada Promecam site and environmental preparation

Press brakes installation requires a stable, rigid ground surface.
Flooring in the work area should be a 50 mm thick concrete slab, with a plane surface (maximum
tolerance 2 mm per meter). For the installation conditions please consult the Amada technical department.

Access to the press should be provided on all four sides:

– At the back leave a space of approximately 1 meter for maintenance operations and adjustments.
– On at least one of the sides provide for space slightly above the maximum bending length, so
that lateral withdrawal removal of some parts is allowed on the whole press brake length
(dimension A, Figure1).Amada press brake site prep

Please see chapter on characteristics for other specifications.

Amada Press Brake Size Specs

BACK TO AMADA PROMECAM HYDRAULIC PRESS BRAKE TECHNICAL MANUAL

Back to 3) AMADA PROMECAM INSTALLATION REQUIREMENTS

Continue to 5) INSTALLATION AND TAKING DELIVERY

Download the full Amada Promecam ITS Hydraulic Press Brake 45899 Manual

Do you need an Amada Promecam Press Brake Retrofit or a New Press Brake?

Automec, Inc. can help!   We are the industry leader in retrofitting press brakes and shears.  Our positioning systems consist of a programmable control where the operator enters a dimension and a motorized gauging mechanism automatically moves through a sequence of programmed dimensions. These systems can be retrofitted to press brakes, shears, cut-off saws and punches.

Whether you need a press brake retrofit or a new press brakecontact us at (781) 893-3403 for help.